We have collected information about Whole Body Dose From Tomotherapy Delivery for you. Follow the links to find out details on Whole Body Dose From Tomotherapy Delivery.
https://www.ncbi.nlm.nih.gov/pubmed/9747842
Aug 01, 1998 · CONCLUSION: The whole-body dose equivalent from a tomotherapy treatment is greater than that from conventional radiation therapy. Further studies are required to assess the trade-off between improved dose distribution conformality and a possible slight increase in radiation-induced fatal malignancies.Author: Sasa Mutic, Daniel A. Low
https://www.sciencedirect.com/science/article/pii/S0360301698001990
The accuracy of using fixed-beam dose distribution data to estimate the whole-body dose resulting from tomotherapy delivery was also assessed. The scattered and leakage doses were determined by assuming that the tomotherapy beam was equivalent to a 10 × 10 cm 2 fixed field and examining the ratio of off-axis to central-axis dose at 40 cm from the field edge and 10 cm depth.Author: Sasa Mutic, Daniel A. Low
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3687380/
Feb 29, 2012 · Therapeutic strategy: The delivery of a total dose of 60 Gy in 30 fractions to the tumour area. Critical organs: eyes, lenses, optic nerves, optic chiasm and brain stem. Table 1 presents basic parameters used in the planning of dose distributions for helical tomotherapy and conventional medical accelerator.Author: Tomasz Piotrowski, Małgorzata Skórska, Agata Jodda, Adam Ryczkowski, Joanna Kaźmierska, Krystyna Ada...
https://www.deepdyve.com/lp/elsevier/whole-body-dose-from-tomotherapy-delivery-diaLh8za0o
The patient dose outside the treatment field is measured in a water-equivalent phantom using thermoluminescent dosimetry. The whole-body dose components from internal scatter and leakage are separately determined. The use of fixed-portal leakage and scattered radiation measurements to estimate the whole-body dose from tomotherapy is evaluated.
https://www.aapm.org/meetings/amos2/pdf/26-5349-99536-381.pdf
tomotherapy dose was less than 0.5% of the target dose, and was between 20% and 30% of the serial tomotherapy leakage dose. This study showed that the whole -body dos e for the 70 Gy is approximately 140 mSv. This dose is less than the 560 mSv for a 70Gy treatment as published by Followill, et al. (Int.J.Radiat.Oncol.Biol.Phys. 38, 667).
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4338216/
Nov 18, 2014 · The integral dose (ID) of radiation delivered to the PTV and whole patient body was defined as a ID [Gy ⋅ L] = D ¯ [Gy] ⋅ V [L], where D ¯ [Gy] is the mean dose delivered to …
Searching for Whole Body Dose From Tomotherapy Delivery?
You can just click the links above. The data is collected for you.