Rapid Exchange Stent Delivery Catheter

We have collected information about Rapid Exchange Stent Delivery Catheter for you. Follow the links to find out details on Rapid Exchange Stent Delivery Catheter.


DIRECT RX Rapid-Exchange Delivery System - Svelte

    http://www.sveltemedical.com/technology/direct-rx/
    DIRECT RX is the first rapid-exchange stent delivery system specifically designed for direct stenting. Incorporating a novel stent design capable of crimping to ultra-low profiles, robust balloon designs to enhance stent delivery and deployment and drug coating technologies with high mechanical integrity, DIRECT RX establishes a higher standard for rapid exchange DES systems.

US5690642A - Rapid exchange stent delivery balloon ...

    https://patents.google.com/patent/US5690642A/en
    A rapid exchange stent delivery balloon catheter which allows exchange from a balloon angioplasty catheter to a stent delivery catheter without the need to replace the angioplasty catheter wire guide with an exchange-length wire guide before exchanging the stent delivery catheter for the balloon angioplasty catheter. The stent delivery catheter of the present invention includes a relatively short wire guide shaft which is bonded to the catheter …Author: Thomas A. Osborne, Scott E. Eells

Xact® Rapid Exchange Carotid Stent System 5.7Fr (1.9mm)

    https://www.accessdata.fda.gov/cdrh_docs/pdf4/P040038c.pdf
    The Xact® Carotid Stent System is comprised of a delivery system and a self-expanding stent. The delivery system is a rapid exchange (RX) system designed to deliver the self-expanding stent to the carotid vasculature. The self-expanding stent is cut from Nitinol tube into a flexible tubular prosthesis.File Size: 1MB

Xperience, Rapid Exchange ballon Catheter by iVascular

    https://ivascular.global/coronary/xperience/
    The Rapid Exchange balloon catheter (RX) xperience, is designed for percutaneous transluminal angioplasty of coronary arteries. The shaft of the catheter features a combination of a single lumen at the proximal end and double lumen at the distal end:

Rapid exchange delivery system for stenting a body lumen ...

    http://www.freepatentsonline.com/5993460.html
    Nov 30, 1999 · A rapid exchange catheter system provides a delivery vehicle to carry a stent through a patient's vasculature and deploy the stent after a protective sheath covering the stent …

Rapid exchange self-expanding stent delivery catheter ...

    http://europepmc.org/patents/PAT/EP1095634
    A self-expanding stent delivery system for medical treatment of a patient has a rapid exchange configuration. The system includes a stent (24), a proximal (14) and distal (16) shaft section, a cartridge (28) for holding the stent compressed until deployment, a stabilizer (34) for holding the stent in position as an outer sheath (30) is retracted, and a flexible tapered (18) introducer tip.

US5468225A - Rapid exchange catheter - Google Patents

    https://patents.google.com/patent/US5468225A/en
    Most rapid exchange catheters have simply used a guidewire channel located near the distal end of the catheter body, through which the guidewire is threaded. From this distal guidewire channel, the guidewire typically simply passes alongside the catheter body to the proximal end of the catheter.Author: Eugene J. Jung, Kenneth Keown, Peter I. C. Turk

Medtronic to Launch Coronary Stents, Balloon Catheters on ...

    https://www.dicardiology.com/content/medtronic-launch-coronary-stents-balloon-catheters-rapid-exchange-us
    Metronic believes offering RX will substantially boost its U.S. stent and balloon catheter sales, since its competitors already offer stents and balloons that use the more popular delivery system. Abbott’s patent on its rapid exchange (RX) delivery system was supposed to expire Oct. 29.

Rx Viatrac 14 Plus Peripheral Dilatation Catheter

    https://www.cardiovascular.abbott/us/en/hcp/products/peripheral-intervention/rx-viatrac-14-plus-dilatation-catheters.html
    RAPID EXCHANGE. Rapid exchange delivery system for single operator use and fast balloon exchanges; Balloon lengths of 15 mm, 20 mm, 30 mm and 40 mm ... When the catheter is exposed to the vascular system, it should be manipulated while under high-quality fluoroscopic observation. ... Stent malapposition or migration, which may require emergency ...

RAPID INSTRUCTIONS FOR USE

    https://www.accessdata.fda.gov/cdrh_docs/pdf3/P030009c.pdf
    lead to stent embolization. The Medtronic Driver Rapid Exchange Coronary Stent System is intended to perform as a system. The Medtronic Driver Stent is not designed to be crimped onto another delivery device. Stent Delivery System should not be used in conjunction with any other stents.

Searching for Rapid Exchange Stent Delivery Catheter?

You can just click the links above. The data is collected for you.

Related Delivery Info