We have collected information about Penumbra Neuron Delivery for you. Follow the links to find out details on Penumbra Neuron Delivery.
https://www.penumbrainc.com/neuro-device/neuron-system/
The Neuron ® Intracranial Access System allows for rapid distal placement into the neurovasculature, providing both robust intracranial support and a wide range of device compatibility.. Penumbra Select ™ Catheters enable Rapid Primary Access into final position, …
https://www.penumbrainc.com/neuro-device/distal-delivery-catheters/
The Penumbra 5MAX™ and 4MAX™ Distal Delivery Catheters (DDC) are designed to simplify therapy delivery to the most distal, tortuous anatomy. The tapered inner shaft maximizes the effective flow lumen to facilitate exceptional angiographic roadmapping. These catheters are offered in three lengths, enabling a wide variety of device compatibility.
https://www.youtube.com/watch?v=XshnjRLT5fc
Jul 22, 2017 · Prior to use, please refer to the Instructions for Use for Penumbra System with 3D Revascularization Device, Penumbra System, Penumbra Pump MAX, Penumbra Delivery Microcatheters, and Neuron MAX ...Author: Penumbra, Inc. US
https://www.accessdata.fda.gov/SCRIPTs/cdrh/cfdocs/cfmaude/detail.cfm?mdrfoi__id=1588990
Upon removing the neuron from the pt and inspection of the catheter, a slight kink was noticed approx 5cm from the distal tip. The kink did not hinder the delivery of the micro catheter, but upon post case inspection the kink seemed significant enough to cause concern.
https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfmaude/detail.cfm?mdrfoi__id=2143998
Immediately after the glue was deployed through the micro-catheter, the physician pulled both the micro-catheter and the neuron back at the same time. As the neuron was pulled back by the proximal end, a crack developed near the hub where the yellow jacket sits over the catheter.
https://sfda.gov.sa/en/medicaldevices/recalls/RecallPages/Pages/6-F1)PenumbraNeuronDeliveryCatheter070.aspx
Penumbra Neuron Delivery Catheter 070. Description. Penumbra Neuron Delivery Catheter 070, percutaneous catheter, catalog numbers PND6F0701058, PND6F070956, PND6F0701058M, and PND6F070956M; manufactured by . Penumbra, Inc., Alameda, CA. Indicated for the introduction of interventional devices into the peripheral, coronary, and neuro vasculature ...
https://investors.penumbrainc.com/investors-relations/events/default.aspx
Penumbra System ® Penumbra JET ™ Family; ACE ™ Family; 3D Revascularization Device ™ MAX ™ Family; Velocity ® Penumbra SMART COIL ® Penumbra Coil 400 ™ Neuron ™ System; BENCHMARK ™ 071; Distal Delivery Catheters; Penumbra Select ™ Catheters; PX SLIM ™ Artemis ™ Neuro Evacuation Device; Penumbra Neuro
https://investors.penumbrainc.com/investors-relations/overview/default.aspx
Penumbra, Inc., headquartered in Alameda, California, is a global healthcare company focused on innovative therapies. Penumbra designs, develops, manufactures and markets innovative products and has a broad portfolio that addresses challenging medical conditions and significant clinical needs across two major markets, neuro and vascular.
https://www.aboutlawsuits.com/penumbra-catheters-recall-neuron-6f-070-delivery-catheter-6238/
Oct 02, 2009 · Older versions of Penumbra Inc.’s Neuron 6F 070 Delivery Catheter have been recalled in the wake of reports that some catheters have kinked, ovalized or broken, resulting in injuries. The Penum
http://www.neuroradialaccess.com/wp-content/uploads/2017/10/Penumbra-BENCHMARK071-Brochure.pdf
BENCHMARK™ 071: Built with ACE™ technology Preload BENCHMARK™ 071 guide catheter with 5F Penumbra Select™ catheter of desired shape. BENCHMARK™ 071 is Now Packaged with a 5F Penumbra Select ™ Catheter Advantages of Select™ Technology • Faster procedures – no need for an exchange • Allows easy selection off of arch into desired vessel, and immediate fi nal placement
Searching for Penumbra Neuron Delivery?
You can just click the links above. The data is collected for you.