https://home.howstuffworks.com/home-improvement/construction/planning/how-long-should-building-house-take1.htm
Pre-construction period. Before you break ground, you have to pull permits, finalize plans and get your financing sorted out. This can take one to two months or longer. When my family got a construction loan recently, it took over a year to find one that worked for us! Preparing the lot and laying the foundation.
https://www.atlantaga.gov/home/showdocument?id=37322
separate building and shall be separated by fire-resistance-rated wall assemblies meeting the requirements of Section R302.1 for exterior walls. Exception: A common 2-hour fire-resistance-rated wall assembly tested in accordance with ASTM E 119 or UL 263 is permitted for townhouses, if such walls do not
http://media.iccsafe.org/Annual/2016/The-Five-Walls-of-the-IBC.pdf
Rating (Hours) Fire Walls and Fire Barriershaving a required fire-resistance rating greater than 1 hour. 4 3 2 1 1/2 3 3ª 1 1/2 1 1/2 Fire Barriers having a required fire-resistance rating of 1 hour. Shaft, exit enclosure and exit passageway walls 11 Other fire barriers 1 3/4 Fire Partitions Corridor walls 1 0.5 1/3ᵇ 1/3ᵇ Other fire partitions 1 0.5 3/4 1/3 Exterior Walls
http://www.johnivison.com/design-and-construction-of-firewalls/
Walls are typically continuous and will have a 2-4 hour rating depending on the occupancy. Traditional firewall construction had good damage resistance to prevent against penetration of the wall by collapsing structure.
https://specsandcodes.typepad.com/the_code_corner/2011/11/fire-walls.html
The construction of the exterior wall below and behind the projecting element must be of 1-hour fire-resistive construction for a distance equal to the depth of the projecting element on each side of the fire wall. Openings within the protected exterior wall area must have a minimum fire protection rating of 45 minutes (See Figure 8).
https://www.woodworks.org/wp-content/uploads/presentation_slides-Fire-Resistant-Design-and-Detailing-Firewalls-Fire-Barriers-and-Fire-Partitions-.pdf
not less than 1 hour. Exception: Corridor walls permitted to have a 1/ 2 hour fire‐resistance rating by Table 1018.1 (applies to R occupancies with sprinkler systems)
https://www.pdhonline.com/courses/g125/g125content.pdf
lists minimum fire resistance,in hours, of various structural components. Section 706.4 of the 2012 IBC requires that if two adjoining buildings have different occupancies then the rating of the firewall must comply with the more restrictive of the two. Fire ratings of construction assemblies can also be found in the Underwriters Laboratory
https://www.awc.org/pdf/codes-standards/publications/wcd/AWC-WCD1-ConventionalWoodFrame-ViewOnly-0107.pdf
DETAILS FOR CONVENTIONAL WOOD FRAME CONSTRUCTION. The first approach to achieving a strong, durable struc-ture, involving economical use of materials, is to follow a ... wall and roof fram-ing where floor and roof trusses are used, and accommodates 24-inch spacing of studs where wind loads
https://en.wikipedia.org/wiki/Firewall_(construction)
Building and structural firewalls in North America are usually made of concrete, concrete blocks, or reinforced concrete.Older fire walls, built prior to World War II, used brick materials.; Fire barrier walls are typically constructed of drywall or gypsum board partitions with wood or metal framed studs.; Penetrations – Penetrations through fire walls, such as for pipes and cables, must be ...