Adiana Delivery Catheter

We have collected information about Adiana Delivery Catheter for you. Follow the links to find out details on Adiana Delivery Catheter.


SUMMARY OF SAFETY AND EFFECTIVENESS DATA (SSED)

    https://www.accessdata.fda.gov/cdrh_docs/pdf7/P070022b.pdf
    thermocouples. The delivery catheter electrodes and thermocouples are arranged on the sheath, one thermocouple is located between 2nd and 3rd bands and the other is between the 1st and 2nd bands. The proximal thermocouple is used as a PMA P070022: FDA Summary of …

Clinical Performance Characteristics of the Adiana® System ...

    https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3046741/
    The Adiana matrix is a biocompatible implant composed of fully cured silicone. Silicone has been shown to be safe and well tolerated for such diverse uses as contraception, 9, 10 cardiac valves, 11, 12 and reconstructive surgery. 13 – 16 The Adiana matrix is housed within the tip of the delivery catheter …Author: Seth J Herbst, Edward G Evantash

Successful placement of the Essure device after a failed ...

    https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3166584/
    The delivery catheter of the Adiana system was able to be inserted into the left fallopian tube without difficulty and per manufacturer specifications. However, the position detection array was unable to sense four-quadrant tissue contact. The same issue occurred at the contralateral tube.Author: Teska Schuurman, Sebastiaan Veersema

Adiana Transcervical Sterilization System Occludes Tubes ...

    https://www.medgadget.com/2007/12/adiana_transcervical_sterilization_system_occludes_tubes_gets_fda_nod.html
    A pre-market application of Adiana Transcervical Sterilization System from Hologic, Inc., a Bedford, Mass company, has received an approval recommendation from the FDA Obstetrics and Gynecology ...

Hologic: Breakthrough Diagnostic & Medical Imaging Solutions

    http://www.hologic.com/
    Hologic is a global champion of women’s health, we integrate The Science of Sure into everything we do to help improve and save lives through early detection and proactive treatment.

Patient Information Booklet - Associates In Women's Health ...

    https://www.aiwhc.com/webdocuments/adiana-patient-information-booklet.pdf
    STEP1:A slender, flexible instrument (delivery catheter) is passed through the body’s natural openings (i.e., through the vagina and cervix and into the uterus) to deliver a low level of radiofrequency energy (i.e., energy that generates heat to create a superficial lesion) to a small section of each fallopian tube.

Adiana Crunchbase

    https://www.crunchbase.com/organization/adiana
    Adiana, Inc. engages in the development and testing of transcervical sterilization system for permanent birth control. It develops Complete TCS, which consists of a radiofrequency generator, delivery catheter, and implantable matrix. The company was founded in 1997 and is based in Redwood City, California.

Operative Hysteroscopy: Overview, Indications ...

    https://emedicine.medscape.com/article/1848467-overview
    Apr 06, 2017 · Adiana (Hologic) procedure. (A): The delivery catheter is inserted into the ostium to the level of the black band. (B) Following delivery of radiofrequency energy, the silicone insert is deployed, and the catheter is removed. (C): Tubal ostium following placement of the insert. Video and images courtesy of Hologic (Bedford, MA).